What It Is & Where It's Used

Vertical turbine pumps are multi-stage pumps with the pumping elements submerged in the fluid source. They use a vertical shaft connecting surface-mounted motors to underwater bowl assemblies, capable of pumping from significant depths with high efficiency.

Municipal water treatment plants, large irrigation systems, industrial cooling water, mine dewatering, and any application requiring high flow from wells, rivers, or reservoirs. Common in applications requiring 500+ GPM.

Common Failures & Warning Signs

Reduced pump capacity
Bearing wear or failure
Bowl and impeller damage
Shaft problems (wear, runout)
Column pipe issues
Discharge head problems
Motor or driver issues
Vibration and alignment problems

How We Diagnose & Fix It

1

Performance Analysis

Compare current output to design specifications.

2

Vibration Testing

Analyze vibration patterns to identify issues.

3

Pull and Inspect

Remove pump column for internal inspection.

4

Detailed Assessment

Evaluate all components and provide options.

5

Expert Repair

Rebuild or replace components as needed.

6

Reinstall and Test

Properly reinstall and verify performance.

Typical turnaround is up to ~2 weeks after inspection and estimate approval.

Maintenance Recommendations

Monitor discharge pressure and flow
Regular vibration analysis
Check motor current and temperature
Lubricate line shaft bearings (oil-lubricated)
Inspect packing or mechanical seal
Annual performance testing

Vertical turbine pumps are critical infrastructure. Our maintenance programs ensure reliable operation and early problem detection.

Frequently Asked Questions

How do I know if my vertical turbine pump needs service?

Declining capacity, increased vibration, unusual noise, or rising energy consumption all indicate service needs.

Can you rebuild vertical turbine pumps on-site?

Minor repairs can be done on-site, but major rebuilds typically require removing the pump for shop work.

What causes bowl assembly wear?

Sand, sediment, cavitation, and normal wear all contribute. We can assess your situation and recommend solutions.

Do you service both oil and water-lubricated designs?

Yes, we have experience with all vertical turbine pump designs and lubrication systems.

Need Help Fast? Call 24/7

Our team is standing by to help with your vertical turbine pumps needs.

After-hours emergency: call Darah at 917-676-7963